Rough Estimate for 1 Residential Building 1 Electrician / floor

D
Dura Cell 👤 Member for 15 years 6 months

Dear All,

For those experience planners, is it possible for 1 electrician + labor / floor to work on residential bldg? 

I am working on rough estimate of manhours on site.



Thanks PP members

 

H
Hannan Mohammed Abdul 👤 Member for 14 years 3 months

Hi,

I would like to prefer the Electrical works to be divided to 1st, 2nd & Final Fix.

for 1st Fix (Embedded items in the slab)-2 Electricians and 4 Helpers

for 2nd Fix(Embedded items in walls and fixtures)-3 Electricians and 6 Helpers

for Final Fix -1 Electrician and 2 Helpers

 

Always consider 2 Helpers with 1 Electrician.

 

 

Regards

Abdul Hannan

A
Andrew Pearce 👤 Member for 24 years 11 months

You need to consider the number of residential units on each floor.

for a simple approximation for a 2bed unit I would allow 2man day to 1st Fix (conduit & wiring prior to plaster), 1 man day 2nd fix fittings & db, 1 man day Final fix, 1 man day test & commission.

K
Konstantinos Parsalidis 👤 Member for 20 years 3 months

Hi there!

Of course it would be, it all depends what they needed to install, how they would do the work, and how much time they'd have to do it...

Regards,

Konstantinos