Hai friends ,
My name is Nageswara Rao
Please tell me oil&gas shutdown WBS and actives
Please tell me
- Printer-friendly version
- Login or register to post comments
- Send to friend
No results found... (try selecting a different content filter)
Comments
Turnaround WBS and Activities
Activities depends upon your scope. And WBS will be like this
1. Category wise ( Electrical, Mechanical, Piping etc.)
2. Area Wise ( Area 1, Area 2 etc..)
3. Unit Wise ( Unit 900, Unit 1000 etc. )
4. Equipment wise ( Exchanger, Vessels, Heater etc.)
And Mostly Activities for equipment will be like this
1. Blinding
2. M/W Opening
3. Cleaning
4. Inspection (NDT also)
5. Repair if any
6. Inspection
7. Boxup
8. Deblinding